Answer six questions about your house and busiest hour, and get the tank size (in gallons and first-hour rating) or the tankless flow rate your home needs, worked out the way the Department of Energy says to, at Raleigh's real incoming water temperature, with a planning price range from our own price book.

Nothing is saved or sent anywhere. It applies the same sizing rules our technicians use; the free in-home quote confirms the number.

Water heater sizing: the short answer

Tanks are sized by the busiest hour. Tankless is sized by what runs at once.

A tank water heater is sized by its first-hour rating: the gallons of hot water it can deliver in one hour starting full. Add up your busiest hour (the Department of Energy counts 20 gallons per shower, 7 for a dishwasher, 15 to 25 for a clothes washer) and buy a tank whose first-hour rating meets it.1 A tankless heater is sized by flow rate at a temperature rise: add up the fixtures running at the same moment (2.5 gallons a minute per shower, 0.75 per faucet) and check what the unit can deliver when it has to lift Raleigh’s 52–57°F incoming water to 120°F.13 Gallons stored and gallons per minute are different questions, which is why the calculator asks both.

20 galHot water the DOE counts for one shower1
2.5 GPMFlow the DOE counts for one shower head1
52–57°FRaleigh’s incoming water most of the year3
~6 GPMWhat a 199,000 BTU Rinnai delivers at that temperature rise2

The calculator

Size yours in about a minute

Six quick questions. You’ll get the busiest-hour gallons your tank has to cover, the gallons per minute a tankless would have to deliver, the size that fits each way, and which one we’d put in your house.

Water heater size calculator

Tank water heaters

Size a tank by its first-hour rating, not its gallons

A “50-gallon” tank doesn’t hand you 50 gallons of hot water. It delivers more than that in a busy hour, because the burner or elements are reheating while you draw, and the exact figure is the first-hour rating printed on the yellow EnergyGuide label as “Capacity (first hour rating).”4 The Department of Energy’s method is to add up your busiest hour and buy a tank whose first-hour rating meets or beats it.1

The DOE peak-hour worksheet

Average gallons of hot water per use, from the DOE worksheet1
UseHot water
Shower20 gallons
Shaving2 gallons
Hand dishwashing or food prep3 gallons
Automatic dishwasher7 gallons
Clothes washer, top-loader25 gallons
Clothes washer, front-load (H-axis)15 gallons

The DOE’s own example: three showers (60), one shave (2) and one round of hand dishes (3) is 66 gallons, so that household needs a first-hour rating of at least 66.1 A large soaking tub isn’t on the worksheet; if you fill one, tell us the tub, because it can take more hot water than a 40-gallon tank holds.

What the standard tanks deliver

First-hour ratings of the standard tanks ARC installs, from Bradford White and State’s own spec sheets (November 2026).67 The EnergyGuide label on the exact model is the final word.
TankFirst-hour ratingCovers a busiest hour of
40-gallon electric53–55 gallons2 showers + a dishwasher
50-gallon electric62–64 gallons2 showers + a front-load washer + dishes
40-gallon gas74–80 gallons3 showers + a front-load washer
50-gallon gas81 gallons4 showers, or 3 + a front-load washer + dishes
Essency EXR (electric, 55-gal footprint)80 gallons4 showers, with no gas line5

Two things the sheets make plain. Gas recovers roughly twice as fast as electric (a 40,000 BTU burner reheats about 43 gallons an hour at a 90°F rise, two 4,500-watt elements about 21), which is why a 40-gallon gas tank out-delivers a 50-gallon electric in the same hour. And on gas, going from a 40 to a 50 adds only a few gallons to the first hour because the burner is the same; the extra storage matters for one big draw like a tub fill, not for the morning line-up. On electric, the jump past a 50-gallon tank is the Essency, not a bigger steel tank.

The quick version by household. On electric: one or two people with two morning showers, a 40-gallon tank; three people, or two showers plus laundry in the same hour, a 50; four showering in the same hour, the Essency. On gas: a 40-gallon tank covers three showers and a load of laundry in the hour, a 50 covers a fourth shower or a tub, and past that (four or more people past age 12, or three or more bathrooms in use) is the household where a tankless, which never runs out, starts to make sense. Run the calculator for your own hour.

Tankless water heaters

Size a tankless by flow rate at Raleigh’s temperature rise

A tankless heater has no reserve, so the busiest hour doesn’t matter; what matters is the most hot water that’s open at the same moment, and how far the unit has to lift the incoming water. The DOE’s method: add up the flow of the fixtures running together (2.5 gallons a minute per shower head, 0.75 per hot faucet), then subtract your incoming water temperature from 120°F to get the temperature rise, and check what the heater delivers at that rise.1

Why “11.1 GPM” on the box isn’t your number

The 11.1 gallons a minute on the Rinnai RX199’s spec sheet is its maximum at a small temperature rise.2 Raleigh’s incoming water runs about 52–57°F most of the year,3 so to make 120°F water the unit has to add 63–68°F, and output drops with the rise. The arithmetic every manufacturer’s chart is built on: gallons a minute = BTU input × efficiency ÷ (500 × °F rise).

One Rinnai RX199 / RXP199 (199,000 BTU, 0.98 UEF) delivering 120°F water
Incoming waterTemperature riseOutput
57°F (Raleigh, warm months)63°F~6.2 GPM
55°F (Raleigh, typical)65°F~6.0 GPM
52°F (Raleigh, cool months)68°F~5.7 GPM
50°F (the DOE’s default assumption)70°F~5.6 GPM

What that covers

Simultaneous demand, using the DOE’s fixture flow rates1
Running at onceNeedsOne RX199
1 shower2.5 GPMEasily
1 shower + a hot faucet3.25 GPMEasily (the DOE’s own example)
2 showers5.0 GPMYes, year-round
2 showers + a faucet or appliance5.75 GPMYes most of the year; tight on the coldest mornings
3 showers7.5 GPMNo. Two units, or a tank

Low-flow 2.0 GPM shower heads move a two-showers-plus-faucet house comfortably inside one unit. The DOE notes that a 70°F rise at about 5 GPM is typical for a gas tankless, and about 2 GPM for an electric one, which is why we don’t put whole-house electric tankless units in.1

The wait at the far bathroom is a different problem. If hot water takes a long time to arrive at the farthest tap, no amount of capacity fixes it; that’s distance. The Rinnai RXP199 has a built-in recirculation pump for exactly that, and a recirculation system can be added to a tank too. The calculator asks about it so it can point you at the right unit. Full details on both Rinnai models, real conversion pricing and what’s included: tankless water heaters.

What we install

Three systems, and the honest reason to pick each

We install three kinds of water heater, and we'll tell you at the kitchen table which one your house needs rather than the one that costs the most. Planning ranges below are from our own flat-rate price book (November 2026); the exact price comes from the free in-home quote and doesn't change once we start.

Every water heater ARC installs carries our own 5-year parts-and-labor warranty on top of the manufacturer's; tanks extend to 10 years when we do the yearly flush. Like-for-like replacements by a licensed plumber need no permit in North Carolina; a change of fuel, capacity, location or venting does, and we pull it. Utility rebates: water heater rebates and credits.

Questions we get

Water heater sizing questions

What size water heater do I need for a family of 4?

Size it by your busiest hour, not the head count. Four people who shower within the same hour use about 80 gallons of hot water by the Department of Energy’s worksheet (20 gallons each), plus 7 for a dishwasher or 15 to 25 for a clothes washer if they run too. That’s right at the limit of a 50-gallon gas tank (81 gallons in the first hour on the current Bradford White and State sheets) and well past a 50-gallon electric (62 to 64). For a family of four on gas, a 50-gallon tank or a Rinnai tankless; on electric, the Essency with its 80-gallon first-hour rating.

What size tankless water heater do I need?

Add up what runs at the same moment (2.5 gallons a minute per shower, 0.75 per hot faucet), then check what the unit delivers at your temperature rise. In Raleigh the incoming water is about 52 to 57°F most of the year, so a 199,000 BTU Rinnai RX199 making 120°F water delivers roughly 5.7 to 6.2 gallons a minute: two showers at once, or two showers and a faucet most of the year. Three showers at once needs two units or a tank.

Is a 40-gallon or 50-gallon water heater better?

Whichever one’s first-hour rating covers your busiest hour. On electric, a 40-gallon tank delivers 53 to 55 gallons in the first hour and a 50 delivers 62 to 64, so two morning showers fits a 40 and two showers plus laundry needs the 50. On gas the two are closer than people expect: a 40 delivers 74 to 80 gallons and a 50 delivers 81, because the burner is the same size; the 50’s extra storage is for a tub fill or a fourth shower, not everyday mornings. Bigger than you need costs more up front and loses more heat standing by, so we don’t oversize.

How do I find the first-hour rating of a water heater?

It’s on the yellow EnergyGuide label, listed as “Capacity (first hour rating),” and in the manufacturer’s spec sheet. It’s the gallons of hot water the heater can deliver in one hour starting from a full tank, and it’s the number to compare against your busiest hour.

What temperature is the incoming water in Raleigh?

About 52 to 57°F most of the year. The Department of Energy’s sizing method assumes 50°F if you don’t know yours, which is a fair worst case for a January morning here. A tankless heater’s output falls as the incoming water gets colder, so we size to the cold case.

Can a tankless water heater run two showers at once?

Yes. Two standard 2.5 GPM showers need 5 gallons a minute, and one Rinnai RX199 delivers about 6 at Raleigh’s incoming water temperature. Add a third shower and the last one cools off; that house gets two units or a tank.

Does a bigger water heater cost more to run?

A bigger tank holds more hot water at temperature around the clock, so it loses a little more heat standing by. The bigger cost is buying capacity you don’t use. Size the tank to the busiest hour, and compare efficiency with the UEF number on the EnergyGuide label.

What size water heater do I need for a 3-bathroom house?

Bathrooms matter less than how many get used in the same hour. Three bathrooms in use in one morning is three showers (60 gallons) plus whatever else runs, which a 40-gallon gas tank (74 to 80 gallons in the first hour) covers with room for laundry, and a 50-gallon electric (62 to 64) does not; on electric that house is Essency territory. If three showers run at the same moment, no single tankless keeps up; that’s a two-unit install or a tank.

Sources

Where the method and the numbers come from

  1. U.S. Department of Energy, Energy Saver. Sizing a New Water Heater: first-hour rating method and peak-hour worksheet (shower 20 gallons, shaving 2, hand dishwashing or food prep 3, dishwasher 7, top-load washer 25, H-axis washer 15); tankless method (0.75 GPM faucet, 2.5 GPM shower head, 120°F output, assume 50°F incoming unless known; a 70°F rise at about 5 GPM is typical for gas, 2 GPM for electric).
  2. Rinnai. RX199iN product page: 199,000 BTU maximum input, 11.1 GPM maximum flow, 0.98 UEF. Output at a given rise on this page = input × UEF ÷ (500 × °F rise), the standard water-heating formula, capped at the published maximum.
  3. ARC Plumbing field figure used on our tankless water heater page: Raleigh incoming water about 52–57°F most of the year, which puts a Rinnai RX199 at roughly 5.7–6.2 GPM per Rinnai’s sizing chart.
  4. State Water Heaters. How to read the EnergyGuide label: the First Hour Rating “indicates the volume of hot water the water heater can deliver within the initial hour.” The label is required by the Federal Trade Commission’s Appliance Labeling Rule (16 CFR 305).
  5. Essency EXR specifications as published on our water heaters page: 55-gallon tank, 80-gallon first-hour rating, two 4,500-watt elements, 240 V / 25 A.
  6. State Water Heaters product pages, read November 5, 2026: ProLine 40-gallon atmospheric gas, GS6-40-BCT (first-hour rating 80 gallons, 40,000 BTU, 0.64 UEF); ProLine 50-gallon atmospheric gas, GS6-50-BRT (81 gallons, 41 GPH recovery, 40,000 BTU, 0.62 UEF); ProLine 40-gallon electric, EN6-40-DORT (53 gallons, 0.92 UEF); ProLine 50-gallon electric, EN6-50-DORT (62 gallons in the tech specs, 0.92 UEF).
  7. Bradford White specification sheets: Residential Atmospheric Vent Gas, form 1101-G-0822 (RG240T6N 40-gallon: first-hour rating 75 gallons, 43 GPH recovery at 90°F rise, 40,000 BTU; RG250T6N 50-gallon: 81 gallons, 43 GPH, 40,000 BTU; a distributor listing of the RG240T6N shows 74) and Residential Electric Upright, form 1201-A-0817 (RE340T6 40-gallon: 55 gallons, 21 GPH at 90°F rise; RE350T6 50-gallon: 64 gallons; two 4,500-watt elements, 0.93 UEF). Bradford White sells only through plumbing professionals, so the sheets are linked from distributor copies: gas sheet, electric sheet.

“Our work is our signature.”